• DocumentCode
    1188043
  • Title

    A New AC Current Testing Method for Non-Destructive Insulation Tests

  • Author

    Terase, H. ; Hirabayashi, S. ; Hasegawa, T. ; Kimura, K.

  • Author_Institution
    The Chubu Electric Power Co. Inc.
  • Issue
    4
  • fYear
    1980
  • fDate
    7/1/1980 12:00:00 AM
  • Firstpage
    1557
  • Lastpage
    1566
  • Abstract
    A new nondestructive diagnosis method is developed mainly for stator coil insulation of high voltage rotating machines as a result of analysis and experience on the behavior of a current of a sample under ac voltage application. A newly-defined parameter Y, measured in this method, equals tan, plus y, where y closely relates to void volume ratio in a sample. A new apparatus to measure Y automatically is also developed which shows experimentally several advantages in a practical test. Y-V patterns and y-V patterns by this method are verified to correlate well to insulation condition and residual breakdown voltage of a sample.
  • Keywords
    Artificial intelligence; Circuit testing; Cities and towns; Coils; Dielectrics and electrical insulation; Insulation testing; Nondestructive testing; Partial discharges; Stators; Voltage;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1980.319581
  • Filename
    4113964