• DocumentCode
    1188989
  • Title

    A Direct-Coupled DC Amplifier Compensated to 20 kc for Use with Photoemissive Devices

  • Author

    Baker, D.J. ; Wyatt, C.L. ; Brown, F.R.

  • fYear
    1964
  • Firstpage
    115
  • Lastpage
    118
  • Abstract
    The relative advantages of the use of a negative-feedback operational amplifier as an electrometer amplifier are investigated. This investigation was made because of the need for a detection system with a frequency response from dc to 20 kc. A theoretical analysis of the compensation circuits used to obtain extended frequency response is given. This analysis indicates a dependence of the compensation networks upon the external capacitive loading. Important practical considerations are given. An expression is derived that gives the compensation network parameters as well as the frequency response in terms of absolute gain of the amplifier.
  • Keywords
    Broadband amplifiers; Capacitance; Circuits; Frequency response; Impedance; Low-noise amplifiers; Operational amplifiers; Pulse amplifiers; Pulse measurements; Transducers;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.1964.4313384
  • Filename
    4313384