• DocumentCode
    1189399
  • Title

    Particulate Emission Control from Pulp Mill Recovery Boilers with Electrostatic Precipitators

  • Author

    Nichols, Grady B.

  • Author_Institution
    Southern Research Institute, Birmingham, AL.
  • Issue
    1
  • fYear
    1977
  • Firstpage
    74
  • Lastpage
    86
  • Abstract
    The theory of electrostatic precipitators as it applies to the collection of particulate from a pulp mill recovery boiler is reviewed. Emphasis is placed on the fundamental physical relationships that exist between the electrical and aerodynamic characteristics of the particulate. A discussion of the difference in the behavior of the precipitator with the conventional and low odor systems is included. A comparison of the design and measured mass efficiency from a number of installations in included.
  • Keywords
    Air pollution; Ash; Boilers; Chemical processes; Electrostatic precipitators; Flue gases; Fuel economy; Milling machines; Power generation economics; Pulp and paper industry;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.1977.4503366
  • Filename
    4503366