• DocumentCode
    1191021
  • Title

    High-Voltage Pulse Reflection-Type Attenuators with Subnanosecond Response

  • Author

    Thomas, Robert J.

  • Volume
    16
  • Issue
    2
  • fYear
    1967
  • fDate
    6/1/1967 12:00:00 AM
  • Firstpage
    146
  • Lastpage
    154
  • Abstract
    Significant advances have been achieved in high-voltage pulse attenuation and measurement fidelity by utilizing the principle of traveling-wave reflection at an abrupt impedance mismatch along a transmission line. Such "reflection-type" attenuators allow practically distortionless attenuation of the signal, independent of voltage level. Their rise-time response and attenuation factor can be known very accurately because they are free from voltage and temperature effects making them especially suited as high-voltage pulse calibration standards. The rise-time response for such attenuators can readily attain 100 ps or less, a practical limit being about 30 ps.
  • Keywords
    Attenuation measurement; Attenuators; Calibration; Distortion measurement; Impedance measurement; Pulse measurements; Reflection; Temperature; Transmission line measurements; Voltage;