DocumentCode :
1192040
Title :
Calibration of a Kerr Cell System for High-Voltage Pulse Measurements
Author :
Cassidy, Esther C. ; Cones, Harold N. ; Wunsch, Donald C. ; Booker, Stanley R.
Volume :
17
Issue :
4
fYear :
1968
Firstpage :
313
Lastpage :
320
Abstract :
Several techniques for calibration of an electrooptical (Kerr cell) high-voltage pulse measuring system are described. Independent calibrations, without reference to pulse divider measurements, are achieved by application of a direct bias voltage to the Kerr cell. After calibration, experiments with voltages as high as 100 kV demonstrate reasonable agreement (to within 1 percent) between simultaneous Kerr cell and calibrated pulse divider measurements.
Keywords :
Calibration; Electric variables measurement; Electrodes; Frequency measurement; Nonlinear optics; Optical modulation; Optical polarization; Optical pulses; Pulse measurements; Voltage measurement;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.1968.4313725