Title :
Improved measurement with 2-D rotating fluxes considering the effect of internal field
Author :
Zhong, Jin Jiang ; Zhu, Jian Guo ; Guo, You Guang ; Lin, Zhi Wei
Author_Institution :
Center for Electr. Machine & Power Electron., Univ. of Technol., Sydney, NSW, Australia
Abstract :
This paper analyzes the effect of the internal field on the measurement with two-dimensional (2-D) rotating fluxes. It is demonstrated that due to the effect of the internal field, the misalignment of H sensing coils, causing the asymmetry of H loci and the discrepancy of the rotational core losses between two opposite rotating directions cannot be corrected completely. A numerical averaging method is employed to eliminate the angular error. Finally, the B and H loci and rotational core losses of a soft magnetic composite (SMC) material were measured under circular rotating magnetic flux density vectors, and the results were corrected by the proposed averaging method.
Keywords :
magnetic field measurement; magnetic flux; magnetic sensors; 2D rotating fluxes; B loci; H loci; H sensing coils; field metric method; internal field effect; magnetic flux density vectors; misalignment angle; numerical averaging method; rotating flux measurement; rotational core losses; soft magnetic composite material; Coils; Composite materials; Core loss; Magnetic field measurement; Magnetic flux; Magnetic materials; Rotation measurement; Sliding mode control; Soft magnetic materials; Two dimensional displays; Field metric method; SST; internal field; magnetization; misalignment angle; rotational core loss;
Journal_Title :
Magnetics, IEEE Transactions on
DOI :
10.1109/TMAG.2005.854917