• DocumentCode
    1194048
  • Title

    The Measurement and Instantaneous Display of Bubble-Size Distribution, Using Scattered Light

  • Author

    Landa, I. ; Tebay, E.S.

  • Volume
    21
  • Issue
    1
  • fYear
    1972
  • Firstpage
    56
  • Lastpage
    59
  • Abstract
    The need for an instrument that measures the bubble distribution in a flow is well documented by the numerous studies that are conducted on cavitation inception and cavitation damage to materials. The present measurement techniques do not provide a complete solution to these problems. In this short paper, we have developed an instrument that determines the bubble-size distribution by measuring the intensity of light scattered from the bubbles. Bubbles in the range of 0.005 to 0.04 in in diameter were measured with this method. The lower limit of this range can be extended by decreasing the factors that contribute noise to the measurement.
  • Keywords
    Absorption; Capacitors; Circuit testing; Dielectric measurements; Displays; Light scattering; Nuclear electronics; Optical receivers; Optical scattering; Voltage;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.1972.4313957
  • Filename
    4313957