DocumentCode
1197111
Title
Digital Wattmeter Using a Sampling Method
Author
Turgel, Raymond S.
Volume
23
Issue
4
fYear
1974
Firstpage
337
Lastpage
341
Abstract
Average electric power can be measured by a system that samples voltages and currents at predetermined intervals. The sampled signals are digitized and the result is computed by numerical integration. The response of the system agrees with that of a standard electrodynamic wattmeter within 0.02 percent from dc to 1 kHz, with the possible exception of zero power factor measurements. Measurements up to 5 kHz can be made with somewhat greater uncertainties.
Keywords
Current measurement; Electric variables measurement; Electrodynamics; Electrostatic measurements; Measurement standards; NIST; Power measurement; Sampling methods; Voltage; Wattmeters;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on