DocumentCode
1197240
Title
Direct-Reading Swept-Frequency Slotted-Line System with Slope Correction
Author
Stauffer, George H., Jr. ; Weinert, Fritz K. ; Weinschel, Bruno O. ; Woodruff, Donald D.
Volume
23
Issue
4
fYear
1974
Firstpage
394
Lastpage
399
Abstract
Many broad-band devices unfortunately exhibit voltage standing wave ratio (VSWR) spikes within narrow frequency bands, and such devices should be tested continuously over the whole frequency range to identify the spikes. The time required for testing is important and a direct-reading display, or record, is a major convenience. The system described uses a swept-frequency slotted-line technique to give a direct-reading record of VSWR over the frequency range 2-18 GHz within 30 s, without degrading the accuracy of the technique.
Keywords
Coaxial components; Degradation; Directional couplers; Displays; Frequency measurement; Narrowband; Performance evaluation; System testing; Time measurement; Voltage measurement;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.1974.4314320
Filename
4314320
Link To Document