DocumentCode
1198341
Title
Analysis of the ITER superconducting coils: magnetic field, AC losses and cooling
Author
Bottura, L. ; Mszanowski, U. ; Mitchell, N.
Author_Institution
Max-Planck-Inst. fuer Plasmaphys., Garching, Germany
Volume
28
Issue
1
fYear
1992
fDate
1/1/1992 12:00:00 AM
Firstpage
230
Lastpage
233
Abstract
The authors present a procedure for the analysis of the operating margin of a pulsed magnet, based on the sequential calculation of magnetic field, AC losses, temperature, temperature margin, and energy margin. The procedure is suited to the analysis of supercritical helium, force-flow cooled magnets. An example of application to the ITER (International Thermonuclear Experimental Reactor) central solenoid and the diverter coils is given, showing the capabilities achieved by an integrated analysis code and the level of detail in the information gained
Keywords
Tokamak devices; composite superconductors; cooling; eddy current losses; fusion reactor theory and design; magnetic leakage; superconducting magnets; temperature distribution; AC losses; ITER superconducting coils; International Thermonuclear Experimental Reactor; cable coupling; central solenoid; diverter coils; eddy currents; energy margin; force-flow cooled magnets; integrated analysis code; magnetic field; multifilamentary superconductors; operating margin; pulsed magnet; strand hysteresis; temperature margin; Helium; Inductors; Information analysis; Magnetic analysis; Magnetic fields; Magnetic losses; Solenoids; Superconducting coils; Superconducting magnets; Temperature;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/20.119852
Filename
119852
Link To Document