• DocumentCode
    1198773
  • Title

    Problems of quench detection in the ITER magnet system

  • Author

    Zhelamsky, Y.V. ; Lebedev, A.A. ; Trokhachev, G.V.

  • Author_Institution
    D.V. Efremov Sci. Res. Inst. of Electrophys. Apparatus, Leningrad, USSR
  • Volume
    28
  • Issue
    1
  • fYear
    1992
  • fDate
    1/1/1992 12:00:00 AM
  • Firstpage
    244
  • Lastpage
    246
  • Abstract
    A preliminary analysis of the peculiarities of the ITER (International Thermonuclear Experimental Reactor) magnet system quench diagnostics has been carried out. The main factors limiting quench detection sensitivity are described. Ways to develop special diagnostic methods for increasing protection system reliability and noise rejection are outlined
  • Keywords
    Tokamak devices; fusion reactor theory and design; quenching (thermal); superconducting magnets; transients; International Thermonuclear Experimental Reactor; detection sensitivity; magnet system; noise rejection; protection system reliability; quench detection; Availability; Current measurement; Detectors; Inductance; Magnetic separation; Power measurement; Power system protection; Superconducting coils; Superconducting magnets; Threshold voltage;