DocumentCode :
1198773
Title :
Problems of quench detection in the ITER magnet system
Author :
Zhelamsky, Y.V. ; Lebedev, A.A. ; Trokhachev, G.V.
Author_Institution :
D.V. Efremov Sci. Res. Inst. of Electrophys. Apparatus, Leningrad, USSR
Volume :
28
Issue :
1
fYear :
1992
fDate :
1/1/1992 12:00:00 AM
Firstpage :
244
Lastpage :
246
Abstract :
A preliminary analysis of the peculiarities of the ITER (International Thermonuclear Experimental Reactor) magnet system quench diagnostics has been carried out. The main factors limiting quench detection sensitivity are described. Ways to develop special diagnostic methods for increasing protection system reliability and noise rejection are outlined
Keywords :
Tokamak devices; fusion reactor theory and design; quenching (thermal); superconducting magnets; transients; International Thermonuclear Experimental Reactor; detection sensitivity; magnet system; noise rejection; protection system reliability; quench detection; Availability; Current measurement; Detectors; Inductance; Magnetic separation; Power measurement; Power system protection; Superconducting coils; Superconducting magnets; Threshold voltage;
fLanguage :
English