• DocumentCode
    1198835
  • Title

    Factors affecting transient overvoltages of electric submersible pumps

  • Author

    Metwally, Ibrahim A. ; Gastli, Adel

  • Author_Institution
    Dept. of Electr. Eng., Mansoura Univ.
  • Volume
    25
  • Issue
    5
  • fYear
    2006
  • Firstpage
    13
  • Lastpage
    17
  • Abstract
    This article presents a theoretical simulation and analysis of all possible factors due to transient overvoltages (TOVs) that could contribute to electrical failures of electric submersible pump (ESP) motors used in oil fields. A transient calculations software package PSCAD is used to simulate a single cable-fed, 3.3-kV induction motor including the mains of the 33-kV distribution system. The factors studied are cable length, earthing resistance and parameters (insulation permittivity and permeability), opening time of CB and its location, switching via pre-insertion resistance, characteristics of the TVSS and its internal structure, and transformer connections and ratings
  • Keywords
    distribution networks; earthing; failure analysis; induction motors; oil technology; overvoltage; power cables; power system CAD; power system simulation; power system transients; power transformers; pumps; 3.3 kV; 33 kV; CB location; PSCAD software package; TVSS characteristics; cable-fed induction motor; distribution system; earthing resistance; electric submersible pump motor; electrical failures; oil field; transformer; transient overvolatage; Analytical models; Cable TV; Electrostatic precipitators; Failure analysis; Power cable insulation; Power cables; Power transformer insulation; Surges; Transient analysis; Underwater vehicles;
  • fLanguage
    English
  • Journal_Title
    Potentials, IEEE
  • Publisher
    ieee
  • ISSN
    0278-6648
  • Type

    jour

  • DOI
    10.1109/MP.2006.1692279
  • Filename
    1692279