DocumentCode
1199970
Title
Transcontinental and Intercontinental Portable Clock Time Comparison
Author
Hellwig, Helmut W. ; Allan, David W. ; Stein, Samuel R. ; Prichard, Kim A.
Volume
27
Issue
1
fYear
1978
fDate
3/1/1978 12:00:00 AM
Firstpage
65
Lastpage
68
Abstract
Because of the relatively low transportation costs of the rubidium portable clock, a schedule of relatively frequent comparisons with two of the main counterparts of NBS (Boulder, CO) have been executed: nearly monthly comparisons with the U. S. Naval Observatory (USNO) in Washington, DC, and trips every quarter year to the International Time Bureau (BIH) in Paris, France. The measurement results of the USNO and BIH comparisons are analyzed as a time series using a least squares quadratic fit. The measurements (time readings) yield a standard deviation of about 100 ns and indicate time scale drifts of about 1 Ã 10-13 per year. Comparison with Loran-C data demonstrates the superior time comparison ability of portable clock trips, exceeding that of Loran-C by up to one order of magnitude.
Keywords
Atomic clocks; Costs; Frequency; Laboratories; NIST; Satellites; Stability; Time measurement; Timing; Transportation;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.1978.4314619
Filename
4314619
Link To Document