• DocumentCode
    1200542
  • Title

    The Determination of Operating Data and Allowable Ratings of Vacuum-Tube Rectifiers

  • Author

    Frommer, J.C.

  • Volume
    29
  • Issue
    9
  • fYear
    1941
  • Firstpage
    481
  • Lastpage
    485
  • Abstract
    Among the operating data of thermionic rectifiers only transformer voltage, output voltage, and output current are readily accessible. In determining the permissible limits of operation however, peak current, inverse voltage, and plate dissipation must be considered. This paper gives formulas and a graph to determine these latter values from the former, to rate limits of operation, and to draw the dynamic characteristics for any valve.
  • Keywords
    Anodes; Cathodes; Current measurement; Electrical resistance measurement; Equations; Inductors; Rectifiers; Surges; Valves; Voltage;
  • fLanguage
    English
  • Journal_Title
    Proceedings of the IRE
  • Publisher
    ieee
  • ISSN
    0096-8390
  • Type

    jour

  • DOI
    10.1109/JRPROC.1941.231313
  • Filename
    1694332