• DocumentCode
    1201012
  • Title

    Operation of a Thyratron as a Rectifier

  • Author

    Ware, L.A.

  • Author_Institution
    Department of Electrical Engineering, State University of Iowa, Iowa City, Iowa
  • Volume
    30
  • Issue
    11
  • fYear
    1942
  • Firstpage
    500
  • Lastpage
    502
  • Abstract
    The half-wave thyratron rectifier circuit is treated theoretically taking into account the difference between the firing potential and the tube drop during conduction. Four loads are considered ranging from a pure resistance to a pure inductance, the impedance angles being 0, 59.15, 85.6, and 90 degrees. The first three of these are checked oscillographically and good correspondences are obtained between (1) calculated average current and measured current and (2) oscillographic waveshape of current and calculated waveshape. It is also noted that errors in the current calculation due to erroneous values of Ef(firing potential) are higher for loads of higher impedance angles.
  • Keywords
    Circuits; Continuous wavelet transforms; Current measurement; Electrical resistance measurement; Equations; Impedance; Inductance; Rectifiers; Thyratrons; Voltage;
  • fLanguage
    English
  • Journal_Title
    Proceedings of the IRE
  • Publisher
    ieee
  • ISSN
    0096-8390
  • Type

    jour

  • DOI
    10.1109/JRPROC.1942.233016
  • Filename
    1694391