DocumentCode
1201012
Title
Operation of a Thyratron as a Rectifier
Author
Ware, L.A.
Author_Institution
Department of Electrical Engineering, State University of Iowa, Iowa City, Iowa
Volume
30
Issue
11
fYear
1942
Firstpage
500
Lastpage
502
Abstract
The half-wave thyratron rectifier circuit is treated theoretically taking into account the difference between the firing potential and the tube drop during conduction. Four loads are considered ranging from a pure resistance to a pure inductance, the impedance angles being 0, 59.15, 85.6, and 90 degrees. The first three of these are checked oscillographically and good correspondences are obtained between (1) calculated average current and measured current and (2) oscillographic waveshape of current and calculated waveshape. It is also noted that errors in the current calculation due to erroneous values of Ef (firing potential) are higher for loads of higher impedance angles.
Keywords
Circuits; Continuous wavelet transforms; Current measurement; Electrical resistance measurement; Equations; Impedance; Inductance; Rectifiers; Thyratrons; Voltage;
fLanguage
English
Journal_Title
Proceedings of the IRE
Publisher
ieee
ISSN
0096-8390
Type
jour
DOI
10.1109/JRPROC.1942.233016
Filename
1694391
Link To Document