DocumentCode :
1201012
Title :
Operation of a Thyratron as a Rectifier
Author :
Ware, L.A.
Author_Institution :
Department of Electrical Engineering, State University of Iowa, Iowa City, Iowa
Volume :
30
Issue :
11
fYear :
1942
Firstpage :
500
Lastpage :
502
Abstract :
The half-wave thyratron rectifier circuit is treated theoretically taking into account the difference between the firing potential and the tube drop during conduction. Four loads are considered ranging from a pure resistance to a pure inductance, the impedance angles being 0, 59.15, 85.6, and 90 degrees. The first three of these are checked oscillographically and good correspondences are obtained between (1) calculated average current and measured current and (2) oscillographic waveshape of current and calculated waveshape. It is also noted that errors in the current calculation due to erroneous values of Ef(firing potential) are higher for loads of higher impedance angles.
Keywords :
Circuits; Continuous wavelet transforms; Current measurement; Electrical resistance measurement; Equations; Impedance; Inductance; Rectifiers; Thyratrons; Voltage;
fLanguage :
English
Journal_Title :
Proceedings of the IRE
Publisher :
ieee
ISSN :
0096-8390
Type :
jour
DOI :
10.1109/JRPROC.1942.233016
Filename :
1694391
Link To Document :
بازگشت