DocumentCode :
1201421
Title :
Study of recovery phenomena in a high-current pulse-triggered vacuum switch
Author :
Bauville, Gérard ; Delmas, Alain ; Haddad, Nabil ; Rioux, Christian
Author_Institution :
Lab. d´´Electrotech., Paris VI Univ., Orsay, France
Volume :
17
Issue :
5
fYear :
1989
fDate :
10/1/1989 12:00:00 AM
Firstpage :
781
Lastpage :
785
Abstract :
The recovery capacities of a triggered vacuum switch after the crossing of a 25-μs high-current pulse were investigated. The recovery time is less than 100 μs. An experiment was conducted with several electrodes with different gaps, and the influence of an axial magnetic field on the switch was studied. A diffuse arc mode was achieved, making possible a commutation power as high as 109 VA
Keywords :
plasma switches; plasma transport processes; 100 ps; 25 ps; axial magnetic field; commutation power; diffuse arc mode; high-current pulse-triggered vacuum switch; recovery phenomena; Capacitors; Cathodes; Circuit testing; Coils; Electrodes; Energy storage; Inductors; Magnetic fields; Switches; Voltage;
fLanguage :
English
Journal_Title :
Plasma Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-3813
Type :
jour
DOI :
10.1109/27.41203
Filename :
41203
Link To Document :
بازگشت