DocumentCode :
1201463
Title :
An Electronic Ratio Error Set for Current Transformer Calibrations
Author :
Kahler, Richard L.
Volume :
28
Issue :
2
fYear :
1979
fDate :
6/1/1979 12:00:00 AM
Firstpage :
162
Lastpage :
164
Abstract :
A direct-reading electronic ratio error set for current transformer calibrations is described. It is capable of generating direct and quadrature error currents from 1 ppm to 5 percent of transformer secondary currents up to 10 A. The uncertainty is less than one percent of the generated current. The set features electronic display of the direct and quadrature components with three digits each and is direct reading at 50, 60, and 400 Hz.
Keywords :
Calibration; Circuits; Current transformers; DC generators; Displays; Frequency; Impedance; Resistors; Switches; Voltage;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.1979.4314787
Filename :
4314787
Link To Document :
بازگشت