• DocumentCode
    1202309
  • Title

    Estimating Effect of System Harmonics on Losses and Temperature Rise of Squirrel-Cage Motors

  • Author

    Cummings, Paul G.

  • Author_Institution
    General Electric Company, Building 50-328, 1 River Road, Schenectady, NY 12345.
  • Issue
    6
  • fYear
    1986
  • Firstpage
    1121
  • Lastpage
    1126
  • Abstract
    With increasing application of static converter power supplies the magnitude of harmonic voltages to which other motors connected to the power system will be exposed must be considered. The additional losses and heating that will occur in these motors may require derating. A simplified expression defined as the harmonic voltage factor (HVF) for estimating the effect of harmonic voltages on polyphase squirrel-cage motors is developed.
  • Keywords
    Equivalent circuits; Frequency; Induction motors; Petroleum; Power system harmonics; Rotors; Stators; Synchronous motors; Temperature; Voltage;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.1986.4504843
  • Filename
    4504843