DocumentCode :
1203323
Title :
Automatic Computation of the Cardiothoracic Ratio with Application to Mass Screening
Author :
Sezaki, Nobuhiko ; Ukena, Kohji
Author_Institution :
Advanced Development Laboratories, Matsushita Communication Industrial Co., Ltd., Yokohama, Japan.
Issue :
4
fYear :
1973
fDate :
7/1/1973 12:00:00 AM
Firstpage :
248
Lastpage :
253
Abstract :
An algorithm for the automatic computation of the cardiothoracic ratio is presented. In experiments using 100 sheets of 14-by 14-in postero-anterior chest radiographs, a tolerable error of ±4 percent was satisfied in 86 percent of all trials. The processing time is about 1 s. The goal of this study is to provide radiologists with practical Instruments for the automated mass screening of heart disease. A minicomputer and a conventional vidicon camera are used in the experimental system.
Keywords :
Automatic control; Cameras; Cardiac disease; Cardiology; Heart; Instruments; Microcomputers; Radio control; Radiography; Thorax; Automation; Computers; Diagnostic Errors; Heart Diseases; Mass Screening; Radiography; Thorax;