• DocumentCode
    1203350
  • Title

    Bridge Sampling Methods for Admittance Measurements from 500 kHz to 5 GHz

  • Author

    Cole, Robert H.

  • Volume
    32
  • Issue
    1
  • fYear
    1983
  • fDate
    3/1/1983 12:00:00 AM
  • Firstpage
    42
  • Lastpage
    47
  • Abstract
    A two-channel time-domain sampler with common time base is used to compare voltages in coaxial lines driven by matched ratio arms from a pulse or sine-wave generator and terminated by unknown and reference admittances. Linear circuit analysis shows that the unknown can be determined from the bridge unbalance sampler outputs by simple calibrations of three frequency-dependent parameters. Design and uses of cells for dielectric measurements and reference terminations are described. Procedures for and results of test measurements are presented for time-domain measurements using a symmetrical power divider as ratio arms and for frequency-domain measurements using a 5O-¿ power splitter and 5-pF capacitative ratio arms.
  • Keywords
    Admittance measurement; Arm; Bridge circuits; Coaxial components; Dielectric measurements; Frequency measurement; Power measurement; Sampling methods; Time domain analysis; Voltage;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.1983.4315007
  • Filename
    4315007