DocumentCode
1203350
Title
Bridge Sampling Methods for Admittance Measurements from 500 kHz to 5 GHz
Author
Cole, Robert H.
Volume
32
Issue
1
fYear
1983
fDate
3/1/1983 12:00:00 AM
Firstpage
42
Lastpage
47
Abstract
A two-channel time-domain sampler with common time base is used to compare voltages in coaxial lines driven by matched ratio arms from a pulse or sine-wave generator and terminated by unknown and reference admittances. Linear circuit analysis shows that the unknown can be determined from the bridge unbalance sampler outputs by simple calibrations of three frequency-dependent parameters. Design and uses of cells for dielectric measurements and reference terminations are described. Procedures for and results of test measurements are presented for time-domain measurements using a symmetrical power divider as ratio arms and for frequency-domain measurements using a 5O-¿ power splitter and 5-pF capacitative ratio arms.
Keywords
Admittance measurement; Arm; Bridge circuits; Coaxial components; Dielectric measurements; Frequency measurement; Power measurement; Sampling methods; Time domain analysis; Voltage;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.1983.4315007
Filename
4315007
Link To Document