DocumentCode :
1203358
Title :
Precise Calibration of Ratio Transformers
Author :
Thompson, Arthur Melville
Volume :
32
Issue :
1
fYear :
1983
fDate :
3/1/1983 12:00:00 AM
Firstpage :
47
Lastpage :
50
Abstract :
The output voltages of a ratio transformer are defined at open-circuit coaxial connectors. A special socket and a difference transformer, wound with coaxial cable, are used to construct a voltage comparator accurate to 1 in 1010. Subdivided transformers are calibrated by comparing the voltage difference between taps with that of an isolated winding on the same transformer. Two similar transformers are compared directly using two voltage comparators.
Keywords :
Admittance; Calibration; Coaxial components; Connectors; Plugs; Sockets; Switches; Switching circuits; Transformers; Voltage;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.1983.4315008
Filename :
4315008
Link To Document :
بازگشت