DocumentCode :
1204152
Title :
Experimental Study of the Frequency Stability of a Maser Oscillator Operated with an External Feedback Loop
Author :
Tetu, Michel ; Tremblay, Pierre ; Lesage, Paul ; Petit, Pierre
Volume :
32
Issue :
3
fYear :
1983
Firstpage :
410
Lastpage :
413
Abstract :
In this paper, we report the results of an experimental study of the short-and mid-term frequency stability for both a hydrogen maser and a rubidium maser operated with an external feedback loop to modify the cavity quality factor. A revised version of the theoretical expression of the frequency stability for this type of maser is given and a numerical solution for various maser parameters is calculated. The predicted frequency stability exhibits an optimum when the cavity Q is varied. The experimental results presented in this study agree with this conclusion.
Keywords :
Feedback loop; Frequency; Hydrogen; Masers; Microwave amplifiers; Oscillators; Q factor; Space technology; Stability; Temperature;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on