DocumentCode
12042
Title
Timekeeping Issues in Ultra-Quality Metering Systems
Author
Haynes, David D. ; Corns, Steven M.
Author_Institution
Syst. Eng., Missouri Univ. of Sci. & Technol., Rolla, MO, USA
Volume
5
Issue
1
fYear
2014
fDate
Jan. 2014
Firstpage
392
Lastpage
393
Abstract
The improvements made to smart metering systems in terms of performance and accuracy have in many cases created a gap in the requirements for timekeeping performance. When clock errors accumulate in different metrology systems, data collected from one system cannot be compared to data collected from another system. This paper recommends the use of a common timebase for all data gathering systems, and that systems clocks are corrected with numerous minor corrections when possible rather than major corrections.
Keywords
clocks; smart meters; clock errors; common timebase; data gathering systems; metrology systems; smart metering systems; timekeeping performance; ultra-quality metering systems; Accuracy; Atomic clocks; Electricity; Metrology; Standards; Time-frequency analysis; Synchronization; telemetry; watthour meters;
fLanguage
English
Journal_Title
Smart Grid, IEEE Transactions on
Publisher
ieee
ISSN
1949-3053
Type
jour
DOI
10.1109/TSG.2013.2288003