DocumentCode :
1206169
Title :
Precise Voltage to Frequency Converter for Telemetry Applications of Strain Gage Pressure Transducers
Author :
Grover, Thomas P.
Author_Institution :
Utah Biomedical Test Laboratory, University of Utah Research Institute, Salt Lake City, Utah 84108.
Issue :
5
fYear :
1975
Firstpage :
441
Lastpage :
443
Abstract :
A voltage to frequency converter suitable for telemetric applications of strain gage pressure transducers is described and analyzed. The circuit uses a voltage reference IC and a temperature dependent op amp bias current to achieve zero pressure offsets less than 3 torr over a 25°C temperature range and a 1 volt supply voltage range.
Keywords :
Bridge circuits; Capacitive sensors; Frequency conversion; Operational amplifiers; Pulse circuits; Pulse modulation; Switches; Telemetry; Transducers; Voltage; Electricity; Pressure; Telemetry; Temperature; Transducers;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/TBME.1975.324521
Filename :
4120960