Abstract :
Timing in peak values shifts slightly between gait trials. When gait data are averaged, part of the standard deviation could be associated with this intertrial variability unless normalization is carried out beforehand. The objective of this study was to determine how continuous curve registration, an alignment technique, can reduce intersubject variability in gait data without altering the original curve characteristics. Gait data were obtained by means of a four-camera high-speed video system synchronized to a force plate. The data for 60 gait trials were collected from 20 young, healthy subjects. Curve registration was applied to hip angular displacement, net moment, and power curves generated in the sagittal plane. Following registration, the peak values increased by an average of 1.2% (0.11 ± 0.26°) for angular displacement, and by 11.2% (0.11 ± 0.09 W/kg) for power, while there were no changes for moments. First and second derivatives of the unregistered and registered curves did not display significant differences, and the harmonics were barely affected. Continuous curve registration would thus be an appropriate technique for application prior to any statistical analysis using able-bodied gait patterns.
Keywords :
biomedical optical imaging; curve fitting; gait analysis; kinematics; muscle; video recording; able-bodied gait patterns; alignment technique; angular displacement; continuous curve registration; first derivatives; force plate; four-camera high-speed video system; gait trials; harmonies; hip angular displacement; intersubject variability; intertrial gait variability reduction technique; net moment; normalization; power curves; registered curves; registration; sagittal plane; second derivatives; statistical analysis; unregistered curves; young healthy subjects; Displays; Hip; Hospitals; Muscles; Orthopedic surgery; Pattern analysis; Physiology; Power generation; Statistical analysis; Timing; Adult; Energy Metabolism; Gait; Hip; Humans; Male; Models, Biological; Models, Statistical; Muscle, Skeletal; Observer Variation; Reproducibility of Results; Rotation; Sensitivity and Specificity; Subtraction Technique; Torque; Video Recording;
fLanguage :
English
Journal_Title :
Neural Systems and Rehabilitation Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
1534-4320
Type :
jour
DOI :
10.1109/TNSRE.2003.810428
Filename :
1200903
Link To Document :
بازگشت