DocumentCode :
1207995
Title :
Markerless real-time 3-D target region tracking by motion backprojection from projection images
Author :
Rohlfing, Torsten ; Denzler, Joachim ; Grassl, C. ; Russakoff, Daniel B. ; Maurer, Calvin R., Jr.
Author_Institution :
Neurosci. Program, Menlo Park, CA, USA
Volume :
24
Issue :
11
fYear :
2005
Firstpage :
1455
Lastpage :
1468
Abstract :
Accurate and fast localization of a predefined target region inside the patient is an important component of many image-guided therapy procedures. This problem is commonly solved by registration of intraoperative 2-D projection images to 3-D preoperative images. If the patient is not fixed during the intervention, the 2-D image acquisition is repeated several times during the procedure, and the registration problem can be cast instead as a 3-D tracking problem. To solve the 3-D problem, we propose in this paper to apply 2-D region tracking to first recover the components of the transformation that are in-plane to the projections. The 2-D motion estimates of all projections are backprojected into 3-D space, where they are then combined into a consistent estimate of the 3-D motion. We compare this method to intensity-based 2-D to 3-D registration and a combination of 2-D motion backprojection followed by a 2-D to 3-D registration stage. Using clinical data with a fiducial marker-based gold-standard transformation, we show that our method is capable of accurately tracking vertebral targets in 3-D from 2-D motion measured in X-ray projection images. Using a standard tracking algorithm (hyperplane tracking), tracking is achieved at video frame rates but fails relatively often (32% of all frames tracked with target registration error (TRE) better than 1.2 mm, 82% of all frames tracked with TRE better than 2.4 mm). With intensity-based 2-D to 2-D image registration using normalized mutual information (NMI) and pattern intensity (PI), accuracy and robustness are substantially improved. NMI tracked 82% of all frames in our data with TRE better than 1.2 mm and 96% of all frames with TRE better than 2.4 mm. This comes at the cost of a reduced frame rate, 1.7 s average processing time per frame and projection device. Results using PI were slightly more accurate, but required on average 5.4 s time per frame. These results are still substantially faster than 2-D to 3-D registrati- - on. We conclude that motion backprojection from 2-D motion tracking is an accurate and efficient method for tracking 3-D target motion, but tracking 2-D motion accurately and robustly remains a challenge.
Keywords :
diagnostic radiography; image motion analysis; image registration; medical image processing; X-ray projection; fiducial marker-based gold-standard transformation; hyperplane tracking; image registration; image-guided therapy; markerless real-time 3-D target region tracking; motion backprojection; normalized mutual information; pattern intensity; projection images; Computed tomography; Costs; Image registration; Medical treatment; Motion estimation; Motion measurement; Mutual information; Robustness; Target tracking; X-ray imaging; 2-D to 2-D registration; 2-D to 3-D registration; Frameless stereotactic radiosurgery; motion backprojection; real-time target tracking; Algorithms; Artifacts; Artificial Intelligence; Computer Systems; Humans; Imaging, Three-Dimensional; Movement; Neuronavigation; Radiographic Image Enhancement; Radiographic Image Interpretation, Computer-Assisted; Radiosurgery; Reproducibility of Results; Sensitivity and Specificity; Subtraction Technique;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/TMI.2005.857651