Abstract
This paper investigates the influence of uncertainties in geometrical coordinates on calculated torso and epicardial potentials. Two types of sources, spherical epicardial and multipolar, are both considered. A concentric sphere model with the epicardial surface represented by a unit sphere and the torso surface represented by a spherical surface of radius 1.4 is utilized. While the representation of biological surfaces with spheres is a highly idealized situation, the dimensions chosen and the approximations utilized are such that the results should be indicative of those using measured biological coordinates.
Keywords
Biological system modeling; Coordinate measuring machines; Electrocardiography; Instruments; Mathematical model; Measurement uncertainty; Position measurement; Root mean square; Solid modeling; Torso; Electrocardiography; Mathematics;