DocumentCode
120953
Title
Comparative study and transient analysis of winding shapes in linear variable differential transformer
Author
Raj, M. Azhagar ; Meera, V. ; Janani, P.
Author_Institution
Eng. services, Hibrise Technol., Chennai, India
fYear
2014
fDate
7-9 Jan. 2014
Firstpage
132
Lastpage
134
Abstract
LVDT is one of the most widely used position sensor. The shape of the winding in LVDT affects flux linkage between primary and secondary. This in turn affects the output voltage which is used to predict the position. The shape of the winding cannot be maintained uniform practically. This paper compares the voltage output of uniform and exponential shape winding implemented in the secondary of LVDT. The transient analysis is performed to study the real time impact of alternating current source and the mechanical motion on output voltage with respect to time. Hence transient analysis is done using Finite Element Electromagnetic tool which provides more accurate prediction when compared with static analysis.
Keywords
differential transformers; finite element analysis; transformer windings; alternating current source; finite element electromagnetic tool; flux linkage; linear variable differential transformer; position sensor; static analysis; transient analysis; winding shapes; Conferences; Exponential winding shape; LVDT; Transient analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Energy Systems (ICEES), 2014 IEEE 2nd International Conference on
Conference_Location
Chennai
Print_ISBN
978-1-4799-3738-7
Type
conf
DOI
10.1109/ICEES.2014.6924155
Filename
6924155