DocumentCode :
1209700
Title :
Simulations and measurements of optical images of insonified ultrasound contrast microbubbles
Author :
Postema, Michiel ; Bouakaz, Ayache ; Chin, Chien Ting ; De Jong, Nico
Author_Institution :
Dept. of Exp. Echocardiography, Erasmus MC-Univ. Med. Center, Rotterdam, Netherlands
Volume :
50
Issue :
5
fYear :
2003
fDate :
5/1/2003 12:00:00 AM
Firstpage :
523
Lastpage :
536
Abstract :
Ultrasound contrast agents (UCAs) are used in a clinical setting to enhance the backscattered signal from the blood pool to estimate perfusion and blood flow. The UCAs consist of encapsulated microbubbles, measuring 1-10 /spl mu/m in diameter. Acoustic characterization of UCAs is generally carried out from an ensemble of bubbles. The measured signal is a complicated summation of all signals from the individual microbubbles. Hence, characterization of a single bubble from acoustic measurements is complex. In this study, 583 optical observations of freely flowing, oscillating, individual microbubbles from an experimental UCA were analyzed. The excursions during ultrasound exposure were observed through a microscope. Images were recorded with a high frame rate camera operating at 3 MHz. Microbubbles on these images were measured offline, and maximal excursions were determined. A technique is described to determine the diameters of the bubbles observed. We compared the maximal excursions of microbubbles of the same initial size in an ultrasound field with a 500 kHz center frequency at acoustic amplitudes ranging from 0.06 MPa to 0.85 MPa. It was concluded that maximal excursions of identical bubbles can differ by 150% at low acoustic pressures (mechanical index or MI<0.2). At a high acoustic pressure (MI=1.2) an image sequence was recorded on which a bubble collapsed, but an apparently identical bubble survived.
Keywords :
biomedical optical imaging; biomedical ultrasonics; blood flow measurement; bubbles; haemorheology; image sequences; optical microscopy; 1 to 10 micron; 3 MHz; 500 kHz; acoustic amplitudes; backscattered signal; blood flow; blood pool; bubble collapse; bubble diameters; clinical setting; encapsulated microbubbles; freely flowing oscillating individual microbubbles; high acoustic pressure; high frame rate camera; image sequence; insonified ultrasound contrast microbubbles; low acoustic pressures; maximal excursions; optical images; perfusion; ultrasound contrast agents; ultrasound exposure; ultrasound field center frequency; Acoustic measurements; Blood flow; Cameras; Echocardiography; Frequency; Microscopy; Myocardium; Optical recording; Ultrasonic imaging; Ultrasonic variables measurement;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/TUFFC.2003.1201465