• DocumentCode
    1210373
  • Title

    Density factor approach to representing impact of die power maps on thermal management

  • Author

    Torresola, Javier ; Chiu, Chia-Pin ; Chrysler, Greg ; Grannes, Dean ; Mahajan, Ravi ; Prasher, Ravi ; Watwe, Abhay

  • Author_Institution
    Intel Corp., Chandler, AZ, USA
  • Volume
    28
  • Issue
    4
  • fYear
    2005
  • Firstpage
    659
  • Lastpage
    664
  • Abstract
    In the microelectronics industry, power has traditionally been the key driver for thermal management. Cooling solutions are typically rated in terms of their power dissipation capacity and efficiency. However, overall power is not the only parameter that affects thermal management. For instance, it is well-known that power density is also important (i.e., it is easier to cool 50 W uniformly distributed on a 20×20 mm die than the same power on a 10×10 mm die). Furthermore, even if the die size remains unchanged, nonuniform power distribution at the die level can create localized regions of high power density that require thermal management. This paper proposes a simple metric, density factor (DFjx), to be used in conjunction with power for quantifying the impact of power density on a given thermal solution. The advantages, limitations, and applicability of this metric are discussed.
  • Keywords
    cooling; micromechanical devices; thermal management (packaging); density factor approach; die power map impact; microelectronics; package thermal resistances; power distribution; thermal management; Cooling; Energy management; Heat sinks; Impedance; Packaging; Power distribution; Temperature; Thermal factors; Thermal management; Thermal resistance; Hotspots; nonuniform heating; package thermal resistances;
  • fLanguage
    English
  • Journal_Title
    Advanced Packaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1521-3323
  • Type

    jour

  • DOI
    10.1109/TADVP.2005.858439
  • Filename
    1528650