DocumentCode :
1211881
Title :
Automatic detection and elimination of periodic pulse shaped interferences in partial discharge measurements
Author :
Nagesh, V. ; Gururaj, B.I.
Author_Institution :
Dept. of High Voltage Eng., Indian Inst. of Sci., Bangalore, India
Volume :
141
Issue :
5
fYear :
1994
fDate :
9/1/1994 12:00:00 AM
Firstpage :
335
Lastpage :
342
Abstract :
The interferences present in partial discharge (PD) measurement can be classified as narrow-band and broad-band, the latter being pulsed shaped. The pulse shaped interferences can be periodic or random with respect to power frequency, the former being very common and strong. The paper describes an algorithm for automatic detection and elimination of periodic pulse shaped interferences in PD measurements. The algorithm is developed on lines similar to that used in decomposing an electromyogram (EMG) into its individual motor unit potentials and is verified with practical and simulated PD measurements. In addition to interference pulse rejection, the algorithm can be used to process data from a digital PD detector for overcoming integration errors, obtaining pulse to pulse time interval histograms and distinguishing different PD pulses based on their waveshapes
Keywords :
charge measurement; computerised instrumentation; interference suppression; partial discharges; signal processing; automatic detection; biomedical signal processing; broad-band interference; clustering; electromyogram; integration errors; interference elimination; narrow-band interference; partial discharge measurements; periodic interference; periodic pulse shaped interferences; pulse time distributions; random interference; waveshapes;
fLanguage :
English
Journal_Title :
Science, Measurement and Technology, IEE Proceedings -
Publisher :
iet
ISSN :
1350-2344
Type :
jour
DOI :
10.1049/ip-smt:19941064
Filename :
338826
Link To Document :
بازگشت