• DocumentCode
    1212284
  • Title

    The Measurement of Gamma Dose with Silicon Junction Counters

  • Author

    Jones, A.R.

  • Author_Institution
    Atomic Energy of Canada Limited, Biology and Health Physics Division, Chalk River, Ontario
  • Volume
    9
  • Issue
    5
  • fYear
    1962
  • Firstpage
    17
  • Lastpage
    22
  • Abstract
    Measurements have been made on three types of silicon Junction counters to assess their application in gamma ray dosimetry. These measurements are presented and it is concluded that each of the three types (high resistivity and guard-ring p-n junction counters and lithium drift counters) are suitable. Their limitations and means of application are also discussed.
  • Keywords
    Atomic measurements; Counting circuits; Dosimetry; Electrons; Energy measurement; Lithium; P-n junctions; Pulse amplifiers; Radiation detectors; Silicon;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IRE Transactions on
  • Publisher
    ieee
  • ISSN
    0096-2015
  • Type

    jour

  • DOI
    10.1109/TNS2.1962.4316059
  • Filename
    4316059