Title :
Direct-reading absolute calibration of AC voltage ratio standards
Author :
Callegaro, Luca ; Bosco, Gian Carlo ; D´Elia, Vincenzo ; Serazio, Danilo
Author_Institution :
Electr. Metrol. Dept., Inst. Elettrotecnico Nazionale Galileo Ferraris, Torino, Italy
fDate :
4/1/2003 12:00:00 AM
Abstract :
A new system for AC voltage ratio absolute calibration has been developed at IEN. The system is based on the simplest possible application of the bootstrap method: during the step-up, the voltage differences are read directly with a vector voltmeter, purposely built to have an extremely high common-mode rejection ratio, exceeding 180 dB at 1 kHz. The system is built around a new two-stage divider, having k:10, k:11 and 1:100 ratios, a two-stage bootstrap transformer (1:10 and 1:11 ratios) with a guarded one-turn secondary stage having adjustable cross-capacitances and a two-secondaries (k:10 and k:11) transformer for easy guarding. The method is insensitive to several possible systematic errors of the voltmeter or coming from the bootstrap operation. The system has been employed during the participation of IEN in the CCEM-K7 key comparison.
Keywords :
bootstrap circuits; measurement standards; measurement uncertainty; transformers; voltage dividers; voltage measurement; voltmeters; 1 kHz; AC voltage ratio standards; CCEM-K7 key comparison; bootstrap method; bootstrap operation; common-mode rejection ratio; cross-capacitances; direct-reading absolute calibration; guarded one-turn secondary stage; systematic error insensitivity; two-secondaries transformer; two-stage bootstrap transformer; two-stage divider; vector voltmeter; voltage differences; voltage dividers; voltage step-up; Calibration; Circuit stability; Electric variables measurement; Frequency conversion; Frequency measurement; Measurement standards; Standards development; Time measurement; Voltage; Voltmeters;
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
DOI :
10.1109/TIM.2003.810716