• DocumentCode
    1213592
  • Title

    The Double Magnetic Induction Method for Measuring Eye Movement - Results in Monkey and Man

  • Author

    Bour, Lo J. ; Gisbergen, Jan A m Van ; Bruijns, Jan ; Ottes, Fenno P.

  • Author_Institution
    Department of Medical Physics and Biophysics, University of Nijmegen
  • Issue
    5
  • fYear
    1984
  • fDate
    5/1/1984 12:00:00 AM
  • Firstpage
    419
  • Lastpage
    427
  • Abstract
    We describe an improved version of the double magnetic induction method for measuring eye movement, proposed by Reulen and Bakker. The idea behind the double magnetic method is to detect eye position indirectly by determining the strength of the induced secondary magnetic field of a short-circuited coil on the subject´s eye caused by a primary magnetic field. A signal related to eye position is obtained from a detection coil, placed in front of the eye, without the need of connecting wires.
  • Keywords
    Animals; Coils; Electromagnetic induction; Electromagnetic measurements; Joining processes; Lenses; Magnetic field measurement; Magnetic fields; Motion measurement; Wires; Animals; Biomedical Engineering; Eye Movements; Haplorhini; Humans; Magnetics; Models, Biological;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.1984.325281
  • Filename
    4121853