Title :
Mixed-signal reflectometer for location of faults on aging wiring
Author :
Tsai, Peijung ; Lo, Chet ; Chung, You Chung ; Furse, Cynthia
Author_Institution :
Dept. of Electr. & Comput. Eng., Univ. of Utah, Salt Lake City, UT, USA
Abstract :
Location of faults on aging cables is of great interest to maintainers of aircraft, cars, power distribution systems, communication systems, etc. One class of methods for locating faults is frequency domain reflectometry (FDR), using sine waves as the forcing function. A new frequency domain method called mixed-signal reflectometry (MSR) is described in this paper and compared to data from phase detection FDR (PDFDR) methods. The MSR is less expensive and smaller than the PDFDR and has very similar performance. A prototype system using the 100-200-MHz bandwidth with 256 40-kHz steps is shown to have a resolution of about 10 cm, very similar to a PDFDR in the same frequency band.
Keywords :
cable testing; electric sensing devices; fault location; frequency-domain analysis; nondestructive testing; reflectometry; 100 to 200 MHz; 40 kHz; aging cable; aging wiring; frequency domain method; frequency domain reflectometry; mixed-signal reflectometer; nondestructive evaluation; phase detection FDR method; sine waves; wire fault location; Aging; Aircraft; Bandwidth; Communication cables; Frequency domain analysis; Phase detection; Power distribution; Prototypes; Reflectometry; Wiring; Nondestructive evaluation; reflectometry; wire fault location;
Journal_Title :
Sensors Journal, IEEE
DOI :
10.1109/JSEN.2005.858894