• DocumentCode
    1215765
  • Title

    Mould and Humidity in Radio and Signals Equipment

  • Author

    Healy, C.P. ; Niven, J.C.

  • Author_Institution
    Amalgamated Wireless (Australasia) Ltd., Ashfield, N.S.W., Australia
  • Volume
    33
  • Issue
    5
  • fYear
    1945
  • fDate
    5/1/1945 12:00:00 AM
  • Firstpage
    300
  • Lastpage
    306
  • Abstract
    Radio equipment constructed by prewar methods and used in areas north of Australia, where the temperature is 75 to 90 degrees Fahrenheit and the average humidity is 90 per cent, does not operate satisfactorily. Mould grows on some parts, while the insulation resistance of others is lowered to unusable values. Fungicides may be used to combat mould growth, but a variety of methods must be adopted to eliminate the effect of humidity on insulation. Methods of test for mould and humidity are dealt with.
  • Keywords
    Australia; Bonding; Fungi; Humidity; Insulation; Land surface temperature; Moisture; Optical materials; Signal design; Testing;
  • fLanguage
    English
  • Journal_Title
    Proceedings of the IRE
  • Publisher
    ieee
  • ISSN
    0096-8390
  • Type

    jour

  • DOI
    10.1109/JRPROC.1945.234236
  • Filename
    1696845