DocumentCode
1215765
Title
Mould and Humidity in Radio and Signals Equipment
Author
Healy, C.P. ; Niven, J.C.
Author_Institution
Amalgamated Wireless (Australasia) Ltd., Ashfield, N.S.W., Australia
Volume
33
Issue
5
fYear
1945
fDate
5/1/1945 12:00:00 AM
Firstpage
300
Lastpage
306
Abstract
Radio equipment constructed by prewar methods and used in areas north of Australia, where the temperature is 75 to 90 degrees Fahrenheit and the average humidity is 90 per cent, does not operate satisfactorily. Mould grows on some parts, while the insulation resistance of others is lowered to unusable values. Fungicides may be used to combat mould growth, but a variety of methods must be adopted to eliminate the effect of humidity on insulation. Methods of test for mould and humidity are dealt with.
Keywords
Australia; Bonding; Fungi; Humidity; Insulation; Land surface temperature; Moisture; Optical materials; Signal design; Testing;
fLanguage
English
Journal_Title
Proceedings of the IRE
Publisher
ieee
ISSN
0096-8390
Type
jour
DOI
10.1109/JRPROC.1945.234236
Filename
1696845
Link To Document