DocumentCode
1215921
Title
The Image Formation in Cathode-Ray Tubes and the Relation of Fluorescent Spot Size and Final Anode Voltage
Author
Liebmann, G.
Author_Institution
Vacuum Research Laboratory, Cathodeon, Ltd., Cambridge, England. (Associated with Pye, Ltd., Cambridge, England)
Volume
33
Issue
6
fYear
1945
fDate
6/1/1945 12:00:00 AM
Firstpage
381
Lastpage
389
Abstract
A new equivalent-optical system consisting of three lenses is proposed to represent the electron-optical system of a cathode-ray-tube gun. The image formation by these lenses is discussed. It is concluded that the fluorescent spot is an image of the cathode and that its size is almost independent of the value of the final anode voltage EA if lens errors can be disregarded. The solid angle of the electron beam proceeding from the second lens to the main focusing lens contracts in inverse proportion to the final accelerating voltage, as expressed by the formula r2EA =constant, r being the radius of the electron beam. Measurements on a number of cathode-ray tubes of widely different design confirm these predictions. The new theory is compared critically with the earlier "cross-over" theory which led to different predictions. Some applications of the new conception to practical, cathode-ray-tube design are briefly discussed.
Keywords
Acceleration; Anodes; Cathode ray tubes; Contracts; Electron beams; Fluorescence; Focusing; Lenses; Solids; Voltage;
fLanguage
English
Journal_Title
Proceedings of the IRE
Publisher
ieee
ISSN
0096-8390
Type
jour
DOI
10.1109/JRPROC.1945.229621
Filename
1696865
Link To Document