• DocumentCode
    1216001
  • Title

    Effect of test method on the failure dose of SEEQ 28C256 EEPROM

  • Author

    Verkasalo, Raimo

  • Author_Institution
    VTT Electron., Oulu, Finland
  • Volume
    41
  • Issue
    6
  • fYear
    1994
  • Firstpage
    2600
  • Lastpage
    2604
  • Abstract
    Two lots of SEEQ 28C256 EEPROM were tested for total dose tolerance. Differences between them were found to result in a dependence of the relative superiority and failure doses of the two lots on the test method and the failure criterion. The failure doses were between 6 and 15 krad, and the failure mechanisms were an increase in the standby current and a loss of programmability.<>
  • Keywords
    CMOS memory circuits; EPROM; failure analysis; integrated circuit reliability; integrated circuit testing; radiation effects; radiation hardening (electronics); 6 to 15 krad; CMOS memory chip; SEEQ 28C256 EEPROM; failure criterion; failure dose; failure mechanisms; programmability loss; standby current increase; test method; total dose tolerance; Annealing; Degradation; EPROM; Electronic equipment testing; Failure analysis; Hospitals; MOS devices; Manufacturing; Qualifications; Radiation hardening;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.340570
  • Filename
    340570