DocumentCode :
1217851
Title :
International comparison GT-RF 78-1: high attenuation (60 dB, 100 dB) at 30 MHz in 50 Ω coaxial line
Author :
Stumpe, Dieter
Author_Institution :
Phys.-Tech. Bundesanstalt, Braunschweig, Germany
Volume :
41
Issue :
3
fYear :
1992
fDate :
6/1/1992 12:00:00 AM
Firstpage :
345
Lastpage :
348
Abstract :
A worldwide comparison of national standard devices in which high attenuation values (up to 100 dB) at the frequency of 30 MHz have been compared is reported. Eleven national laboratories of metrology from the Netherlands, France, Italy, the United Kingdom, Sweden, Poland, Hungary, Australia, the People´s Republic of China, the USSR, and the Federal Republic of Germany participated. The transfer standards were two fixed attenuators with an attenuation of about 60 dB and 100 dB and one switchable attenuator with 100 dB. The maximum difference between any two results is 0.064 dB at an attenuation of 60 dB and 0.125 at 100 dB. For a considerable number of laboratories, the deviation between mean values was not larger than 0.001 dB for a 60-dB attenuation step, and not larger than 0.005 dB for a 100-dB attenuation step
Keywords :
attenuation measurement; coaxial cables; measurement standards; 100 dB; 30 MHz; 50 ohm; 60 dB; Australia; China; France; GT-RF 78-1; Germany; Italy; Netherlands; Sweden; USSR; United Kingdom; attenuation; coaxial line; national standard; transfer standards; Attenuation measurement; Attenuators; Australia; Coaxial components; Connectors; Laboratories; Measurement standards; Metrology; Particle measurements; Radio frequency;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.153326
Filename :
153326
Link To Document :
بازگشت