DocumentCode :
1218886
Title :
RF Energy Deposition in a Heterogeneous Model of Man: Far-Field Exposures
Author :
Stuchly, Stanislaw S. ; Kraszewski, Andrzej ; Stuchly, Maria A. ; Hartsgrove, George W. ; Spiegel, Ronald J.
Author_Institution :
Department of Electrical Engineering, University of Ottawa
Issue :
12
fYear :
1987
Firstpage :
951
Lastpage :
957
Abstract :
Distributions of the specific absorption rate (SAR) were measured in a full-scale heterogeneous model of man. The model contained a skeleton, brain, lungs, and muscle. All these tissues had dielectric properties close to those of the respective in vivo properties of actual tissues at the test frequencies. SAR´s were measured for exposures in the far field at 160, 350, and 915 MHz for the E and H polarizations. A computer-controlled scanning system and an implantable, minimally perturbing electric field probe were used. The results are also compared with the SAR distributions previously measured in a homogeneous model.
Keywords :
Brain modeling; Dielectric measurements; In vivo; Lungs; Muscles; Polarization; Radio frequency; Skeleton; Specific absorption rate; Testing; Biomedical Engineering; Electromagnetic Fields; Humans; Models, Anatomic; Radio Waves;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/TBME.1987.325934
Filename :
4122480
Link To Document :
بازگشت