Combined ultrasound and fluorescence spectroscopy for physico-chemical imaging of atherosclerosis
Author :
Warren, Steve ; Pope, Karl ; Yazdi, Youseph ; Welch, Ashley J. ; Thomsen, Sharon ; Johnston, Alfred L. ; Davis, Michael J. ; Richards-Kortum, Rebecca
Author_Institution :
Biomed. Eng. Program, Texas Univ., Austin, TX, USA
Volume :
42
Issue :
2
fYear :
1995
Firstpage :
121
Lastpage :
132
Abstract :
Describes a combined ultrasonic and spectroscopic system for remotely obtaining physico-chemical images of normal arterial tissue and atherosclerotic plaque. Despite variations in detector-tissue separation, R, fluorescence powers corresponding to pixels in the image are converted to the same set of calibrated units using distance estimations from A-mode ultrasound reflection times. An empirical model, validated by Monte Carlo simulations of light propagation in tissue, is used to describe changes in fluorescence power as a function of R. Fluorescence spectra of normal and atherosclerotic human aorta obtained with this system are presented as a function of R. To compensate for changes in fluorescence power with R, the empirical model was used in each case to calculate the fluorescence power at a constant reference value of R(R ref=1.67 mm). Prior to compensation, tissue fluorescence power decreased more than a factor of two as R was increased from 2.5 to 5 mm. Following compensation. The fluorescence power varied less than ±10% of the average compensated peak. The chemical composition of each sample was determined by fitting its fluorescence spectrum (in calibrated units) to a model of tissue fluorescence incorporating structural protein and ceroid fluorescence, as well as structural protein and hemoglobin attenuation. Parameters of the fit were used to classify tissue type. Without compensation for distance variation, classification of tissue type was frequently incorrect; however, with compensation, predictive value was high. A 1D chemical image of a section of human aorta containing both normal and atherosclerotic regions obtained with this system is also presented. After compensation for detector-sample separation, tissue classifications along the cross-section closely resemble those obtained from histology. Regions of elevated ceroid concentration and intimal thickening are clearly observable in the resultant chemical image. The potential value - - of this type of system in the diagnosis and treatment of coronary artery disease is discussed.
Keywords :
biomedical ultrasonics; fluorescence spectroscopy; 1.67 mm; 2.5 to 5 mm; Monte Carlo simulations; atherosclerosis imaging; atherosclerotic plaque; ceroid fluorescence; combined ultrasonic/spectroscopic system; coronary artery disease diagnosis; detector-tissue separation; empirical model; fluorescence powers; fluorescence spectroscopy; hemoglobin attenuation; light propagation in tissue; normal arterial tissue; physico-chemical imaging; sample chemical composition; structural protein fluorescence; Atherosclerosis; Chemicals; Fluorescence; Humans; Image converters; Pixel; Power system modeling; Proteins; Spectroscopy; Ultrasonic imaging; Aorta; Calibration; Collagen; Coronary Artery Disease; Elastin; Humans; Image Processing, Computer-Assisted; Models, Cardiovascular; Monte Carlo Method; Predictive Value of Tests; Spectrometry, Fluorescence; Ultrasonography;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/10.341824
Filename :
341824
Link To Document :
بازگشت