    Optimization of cardiac defibrillation by three-dimensional finite element modeling of the human thorax

  • Author

    Panescu, Dorin ; Webster, John G. ; Tompkins, Willis J. ; Stratbucker, Robert A.

  • Author_Institution
    EP Technol. Inc., Sunnyvale, CA, USA
  • Volume
    42
  • Issue
    2
  • fYear
    1995
  • Firstpage
    185
  • Lastpage
    192
  • Abstract
    The goal of this study was to determine the optimal electrode placement and size to minimize myocardial damage during defibrillation while rendering refractory a critical mass of cardiac tissue of 100%. For this purpose, the authors developed a 3D finite element model with 55,388 nodes, 50,913 hexahedral elements, and simulated 16 different organs and tissues, as well as the properties of the electrolyte. The model used a nonuniform mesh with an average spatial resolution of 0.8 cm in all three dimensions, To validate this model, the authors measured the voltage across 3-cm 2 Ag-AgCl electrodes when currents of 5 mA at 50 kHz were injected into a human subject´s thorax through the same electrodes. For the same electrode placements and sizes and the same injected current, the finite element analysis produced results in good agreement with the experimental data. For the optimization of defibrillation, the authors tested 12 different electrode placements and seven different electrode sizes. The finite element analyses showed that the anterior-posterior electrode placement and an electrode size of about 90 cm 2 offered the least chance of potential myocardial damage and required a shock energy of less than 350 J for 5-ms defibrillation pulses to achieve 100% critical mass. For comparison. The average cross-sectional area of the heart is ≈48 cm 2, about half of the optimal area. A second best electrode placement was with the defibrillation electrodes on the midaxillary lines under the armpits. Although this placement had higher chances of producing cardiac damage, it required less shock energy to achieve 100% critical mass.
  • Keywords
    bioelectric phenomena; cardiology; finite element analysis; optimisation; patient treatment; physiological models; 3D finite element modeling; 5 mA; 5 ms; 50 kHz; Ag; Ag-AgCl electrodes; AgCl; cardiac damage; cardiac defibrillation optimization; cardiac tissue critical mass; defibrillation pulses; electrode size; electrolyte properties; human thorax; myocardial damage minimization; nonuniform mesh model; optimal electrode placement; shock energy; Cardiac tissue; Current measurement; Defibrillation; Electric shock; Electrodes; Finite element methods; Humans; Myocardium; Spatial resolution; Thorax; Computer Simulation; Electric Conductivity; Electric Countershock; Electrodes; Equipment Design; Humans; Models, Anatomic; Models, Cardiovascular; Thorax;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/10.341831
  • Filename
    341831