Use of Swept Sine Wave in Physiological Systems Analysis
Author :
Laxminarayan, Swamy ; Laxminarayan, Ramanath
Author_Institution :
Laboratory of Physiology, Free University
Issue :
1
fYear :
1978
Firstpage :
103
Lastpage :
105
Abstract :
The use of a swept sine wave as a transient forcing function for measuring the frequency response characteristics of a physiological system is suggested. The spectral characteristics of a linear frequency swept sine wave are illuistrated and it is shown that, with relatively short sweep sine wave excitations, one can obtain almost rectangular modulus spectra with relatively good frequency selectivity. Such a transient method may be of potential use in physiological systems analysis.
Keywords :
Band pass filters; Bandwidth; Frequency measurement; Frequency response; Impedance; Noise shaping; Pulse shaping methods; Transfer functions; Transient analysis; White noise; Mathematics; Methods; Models, Biological;