• DocumentCode
    1221970
  • Title

    Neutral Beam Injection for the Doublet III Device

  • Author

    Kamperschroer, J.H. ; Bhadra, D.K.

  • Volume
    7
  • Issue
    3
  • fYear
    1979
  • Firstpage
    151
  • Lastpage
    157
  • Abstract
    Neutral beam injection into Doublet III has been considered with regard to the calculation of non thermalizing particle orbits and the confinement of such orbits. Injected particle loss, based upon these orbits, toroidal gyro-radius effects, and plasma transparency, is calculated to be on the order of 5 percent for coinjection. Near-perpendicular injection at 80 keV has been chosen with the resulting available injection window of 1014 cm-3 ¿ n(0) ¿ 3 × 1014 cm-3. Injection into plasmas with n(0) ¿ 1014 cm-3 will yield large losses due to the increasing transparency of the plasma, whereas injection into plasmas with n(0) ¿ 3 × 1014 cm-3 shifts the deposition profile toward the plasma edge.
  • Keywords
    Orbital calculations; Orbits; Particle beam injection; Particle beams; Physics; Plasma confinement; Plasma density; Plasma devices; Plasma stability; Plasma temperature;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/TPS.1979.4317220
  • Filename