DocumentCode :
1222564
Title :
Testing of a 100-kV 100-Hz Rep-Rate Gas Switch
Author :
Ramrus, A. ; Shannon, J.
Volume :
8
Issue :
3
fYear :
1980
Firstpage :
160
Lastpage :
162
Abstract :
A two-electrode gas switch with a self-breakdown voltage of 100 kV was operated at a pulse-repetition rate (PRR) of 100 Hz with bursts up to 10 s in duration. The output of a pulse transformer provided the (1 - cos ¿t) waveform which charged the switch in about one-half ms. The switch discharged with a peak current of about 10 kA and a total charge transfer of about 10 mC into a damped LC circuit. A continuous purge of air through the interelectrode spacing enabled the switch to recover its breakdown voltage between discharges. Flow rates up to 35 standard cubic feet per minute (scfm) were employed. This paper discusses the dependence of switch jitter and waveform reproducibility on airflow rate.
Keywords :
Charge transfer; Circuit testing; Diodes; Jitter; Pulse generation; Pulse transformers; Spark gaps; Switches; Switching circuits; Thyratrons;
fLanguage :
English
Journal_Title :
Plasma Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-3813
Type :
jour
DOI :
10.1109/TPS.1980.4317294
Filename :
4317294
Link To Document :
بازگشت