• DocumentCode
    1222752
  • Title

    Tomographic fluorescence imaging in tissue phantoms: a novel reconstruction algorithm and imaging geometry

  • Author

    Roy, R. ; Thompson, A.B. ; Godavarty, A. ; Sevick-Muraca, E.M.

  • Author_Institution
    Photon Migration Labs., Texas A&M Univ., College Station, TX, USA
  • Volume
    24
  • Issue
    2
  • fYear
    2005
  • Firstpage
    137
  • Lastpage
    154
  • Abstract
    A novel image reconstruction algorithm has been developed and demonstrated for fluorescence-enhanced frequency-domain photon migration (FDPM) tomography from measurements of area illumination with modulated excitation light and area collection of emitted fluorescence light using a gain modulated image-intensified charge-coupled device (ICCD) camera. The image reconstruction problem was formulated as a nonlinear least-squares-type simple bounds constrained optimization problem based upon the penalty/modified barrier function (PMBF) method and the coupled diffusion equations. The simple bounds constraints are included in the objective function of the PMBF method and the gradient-based truncated Newton method with trust region is used to minimize the function for the large-scale problem (39919 unknowns, 2973 measurements). Three-dimensional (3-D) images of fluorescence absorption coefficients were reconstructed using the algorithm from experimental reflectance measurements under conditions of perfect and imperfect distribution of fluorophore within a single target. To our knowledge, this is the first time that targets have been reconstructed in three-dimensions from reflectance measurements with a clinically relevant phantom.
  • Keywords
    Newton method; biological tissues; biomedical optical imaging; fluorescence; gradient methods; image reconstruction; medical image processing; optical tomography; phantoms; area collection; area illumination; coupled diffusion equations; fluorescence absorption coefficients; fluorescence-enhanced frequency-domain photon migration tomography; fluorophore distribution; gain modulated image-intensified charge-coupled device camera; gradient-based truncated Newton method; image reconstruction; imaging geometry; modulated excitation light; nonlinear least-squares-type simple bounds constrained optimization; penalty/modified barrier function; reflectance measurements; tissue phantoms; tomographic fluorescence imaging; Area measurement; Current measurement; Fluorescence; Geometry; Image reconstruction; Imaging phantoms; Optical modulation; Reconstruction algorithms; Reflectivity; Single photon emission computed tomography; Area illumination and area collection; image-intensified charge-coupled device; penalty/modified barrier function method; simple bound constraints; truncated Newton method with trust region; Algorithms; Animals; Artificial Intelligence; Connective Tissue; Humans; Image Enhancement; Image Interpretation, Computer-Assisted; Microscopy, Fluorescence; Numerical Analysis, Computer-Assisted; Phantoms, Imaging; Reproducibility of Results; Sensitivity and Specificity; Signal Processing, Computer-Assisted; Spectrophotometry, Infrared; Tomography, Optical;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2004.839359
  • Filename
    1388563