DocumentCode
1222887
Title
Design and performance characteristics of the E769 beamline transition radiation detector
Author
Errede, D. ; Sheaff, M. ; Fenker, H. ; Lueking, L. ; Mantsch, Paul
Author_Institution
Dept. of Phys., Wisconsin Univ., Madison, WI, USA
Volume
36
Issue
1
fYear
1989
fDate
2/1/1989 12:00:00 AM
Firstpage
106
Lastpage
111
Abstract
A transition radiation detector (TRD) was designed and built for E769, a Fermilab fixed target experiment for use in separating pions from protons or kaons in a 250-GeV/c positive beam at the Tagged Photon Laboratory. Requirements placed on the detector were that it operate in a high rate (≈2 MHz) environment and that it be relatively easy to build since it had to be ready approximately one year from the date of its inception. The short time available precluded exposing prototypes to a test beam, making it necessary to rely on source testing and Monte Carlo programs to predict the detector performance. When operated in the beam, the detector performance was in good agreement with these predictions. For a pion detection efficiency of 87%, the contamination by protons of a sample of TRD tagged pions was 2%
Keywords
meson detection and measurement; particle detectors; E769 beamline transition radiation detector; Fermilab fixed target experiment; kaons; pions; protons; Contamination; Laboratories; Mesons; Monte Carlo methods; Particle beams; Physics; Protons; Radiation detectors; Tagging; Testing;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/23.34414
Filename
34414
Link To Document