• DocumentCode
    1223402
  • Title

    The DELPHI high-density projection chamber

  • Author

    Meyer, W.T.

  • Author_Institution
    Ames Lab., IA, USA
  • Volume
    36
  • Issue
    1
  • fYear
    1989
  • fDate
    2/1/1989 12:00:00 AM
  • Firstpage
    352
  • Lastpage
    356
  • Abstract
    The mechanical design (converter, readout chamber, and trigger counters) and electronics (analog components and digitizers) of the High-Density Projection Chamber are described. Results from tests of production modules both in a test beam. showing observed change as a function of incident energy and observed versus expected track location, are presented. Tests using cosmic rays, showing measured drift-velocity and attenuation length for each pad row, are also presented
  • Keywords
    calorimeters; ionisation chambers; nuclear electronics; position sensitive particle detectors; DELPHI; High-Density Projection Chamber; analog components; attenuation length; converter; cosmic rays; digitizers; drift-velocity; electronics; mechanical design; readout chamber; trigger counters; Anodes; Assembly; Cathodes; Circuits; Collaborative work; Laboratories; Production; Sampling methods; Testing; Wire;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.34463
  • Filename
    34463