DocumentCode
1223597
Title
Development of the front end electronics for the ZEUS high resolution calorimeter
Author
Sippach, W. ; Caldwell, A. ; Cunitz, H. ; Kotz, U. ; Moeschen, J.
Author_Institution
Columbia Univ. Nevis Lab., Irvington, NY, USA
Volume
36
Issue
1
fYear
1989
fDate
2/1/1989 12:00:00 AM
Firstpage
465
Lastpage
470
Abstract
The development and design of the pipelined data acquisition system for the high-resolution ZEUS calorimeter are described. Details of the front-end analog card and its performance are presented. A description of the custom pipeline and buffer multiplexer chips is given, along with test results for the pipeline chip. In addition, some results are presented for a CCD (charge-coupled device) test system built to evaluate the pipeline principles using the ZEUS calorimeter prototype at the CERN PS
Keywords
charge-coupled device circuits; data acquisition; nuclear electronics; scintillation counters; CCD; buffer multiplexer chips; charge-coupled device; custom pipeline; front-end analog card; high-resolution ZEUS calorimeter; pipelined data acquisition system; Current measurement; Data acquisition; Delay; Detectors; Dynamic range; Electromagnetic compatibility; Multiplexing; Pipelines; Protons; Testing;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/23.34484
Filename
34484