DocumentCode :
1225412
Title :
Sensorless Control and Fault Diagnosis of Electromechanical Contactors
Author :
Espinosa, Antonio Garcia ; Ruiz, Jordi-Roger Riba ; Cusidó, J. ; Morera, Xavier Alabern
Author_Institution :
Electr. Eng. Dept., Polytech. Univ. of Catalonia, Barcelona
Volume :
55
Issue :
10
fYear :
2008
Firstpage :
3742
Lastpage :
3750
Abstract :
This paper describes a novel algorithm for a closed-loop sensorless control of electromagnetic devices. It integrates a novel fault diagnosis algorithm of the whole electromagnetic circuit. Applied to a contactor with a dc core, it eliminates the armature and contact bounce, whether it is ac or dc powered and at either 50 or 60 Hz. The position and velocity of the moving armature and contacts are calculated by means of the online determination of the inductance using only the measured current and voltage values of the contactor coil as control inputs. A fuzzy controller takes the position and velocity of the armature as input and provides the current set point as output, which controls the velocity of closure of the contacts. The algorithm has been implemented in a low-cost electronic module.
Keywords :
closed loop systems; contactors; electromagnetic devices; fault diagnosis; fuzzy control; velocity control; closed-loop control; contactor coil; current set point; electromagnetic circuit; electromagnetic devices; electromechanical contactors; fault diagnosis algorithm; frequency 50 Hz; frequency 60 Hz; fuzzy controller; inductance; low-cost electronic module; sensorless control; velocity controls; Closed loop; closed loop; closing control; contactor; electromagnetic actuator; fault diagnosis; sensorless control;
fLanguage :
English
Journal_Title :
Industrial Electronics, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0046
Type :
jour
DOI :
10.1109/TIE.2008.925773
Filename :
4526221
Link To Document :
بازگشت